Cooling scheme | Air-cooling type |
---|---|
Cooling capacity (W) *1 | 1300 / 1400 |
Heating capacity (W) *1 | 230 / 350 |
Circulated water *2 | Distilled water, Pure water (1μS/cm or more), Ethylene glycol solution (concentration 15 wt% or less), Propylene glycol solution (concentration 15 wt% or less) |
Temperature stability (℃) *3 | ±0.1 |
Use Area Temperature (℃) | 5~45 |
Circulating water temperature range (℃) | 5 to 40 |
Circulating water rated flow rate (ℓ/min) | 15/15 |
Maximum discharge pump head (m) *4 | 14/20 |
Tank capacity (ℓ) | Approx. 10 |
Dimensions (mm) *5 | H610×W400×D445 |
Coating Color | Munsell N-87 |
Weight (kg) | Approx. 42 |
Casters (Φmm×unit) | 38×4 |
Rated Voltage (V) *6 | 1-phase 200 VAC |
Power Consumption (kW) *1 | 0.60 / 0.73 |
Current consumption (A) *1 | 3.5 / 3.7 |
Recommended breaker capacity (A) | 10 |
Circulating water inlet / outlet port size | Rc1/2 |
Drain discharge port size | G1/2 |
Components / Compressor | Fully sealed rotary type |
Components / Condenser | Fin and tube type |
Components / Evaporator | Structure : Plate-type heat exchanger Material : SUS316 (copper brazing) |
Components / Circulating pump | Structure : Magnetic centrifugal pump Output : 0.180/0.216 (kW) |
Refrigerator | R1234yf 300g |
Noise (dB) *7 | 60 / 60 |
Safety circuit / Compressor | Thermal protector |
Safety circuit/Pump | Thermal protector |
Safety circuit / Fan motor | Thermal protector, Current fuse |
Input / Alarm output | No voltage open-contact (Max. AC250V/1A, DC30V/2A) |
Input/Output / Water temperature upper/lower limit output | No voltage open-contact (Max. AC250V/1A, DC30V/2A) |
Input/Output / Operation stop output | No voltage open-contact (Max. AC250V/1A, DC30V/2A) |
Input/Output / Pump output | No voltage open-contact (Max. AC250V/1A, DC30V/2A) |
Input/Output / Emergency stop input | No-voltage input |
Input/Output / Operation stop input | No-voltage input |
Input/Output / Error reset input | No-voltage input |
Input/Output / External temperature sensor *8 | Pt100 |
Input/Output / Ethernet | 10BASE-T/100BASE-TX Socket(TCP/IP)、MC protocol(UDP/IP)、Modbus TCP |
Display / operation method | Monochrome display, key input |
Log data | Recorded items: Date and time, error number, circulation water set temperature, circulation water outlet temperature, external temperature, chiller run/stop, pump/fan/compressor run/stop, pump independent run status, emergency stop command input terminal status, run-stop command input terminal status, error reset command input terminal status, false warning output status, compressor high-pressure pressure, compressor low-pressure pressure, compressor ejection temperature, compressor intake temperature, water empty sensor status, fan control status, coolant operation volume, high-pressure protection control status, low-pressure protection control status, overheating protection control status, freezing protection control status. Recording period: Approx. 1 year and 6 months Recording interval *9: 2 minute intervals Export method: USB memory, Socket communication |
Functions | Graph display, chiller operation status display, error history display, operation time display, calendar, write memo, water temperature error settings, operation timer settings, password settings, key lock, freeze protection operation, log data USB memory write, external temperature sensor input, cascade control |