Cooling scheme | Air-cooling type |
---|---|
Control models | Temperature control |
Cooling capacity(W) | 6400/7200 |
Thermal capacity(W) | 9100/9900 |
Temperature stability(℃) | ±0.1 |
Setting Temperature Range(℃) | 10 to 50 |
Use Area Temperature(℃) | -5~35 (Temperature change gradient: Within 1℃/1h) |
Use Area Humidity(%RH) | 15~85 (Humidity change gradient: within 5%RH/1h) (No condensation) |
Processed air volume(m3/min) | 20/22 |
External Dimensions(mm) | H1631×W650×D800 |
Weight(kg) | 220 |
Coating Color | Ivory (Y22-85B semi-gloss) |
Blower duct connection diameter(mm) | φ200 (with damper) |
Rated voltage(V) | Three-phase AC 200 |
Consumption Current(A) | 11/12.5(Rated) 14/16(MAX) |
Consumption wattage(W) | 3000/4000(Rated) 4200/5200(MAX) |
Drain connection diameter | 20A female socket (Rp: 3/4 inch) |
Refrigerant(g) | R407C 1700g |
Exhaust air volume(m3/min) | 33/39 |
Safety circuit / Main circuit | Earth leakage breaker (20A 30mA), reverse rotation prevention relay |
Safety circuit / Blower | Overcurrent relay, delay timer (3 minutes), surge absorber |
Safety circuit / Compressor | High and low pressure abnormal pressure protection, overcurrent relay, motor protector (140℃ OFF 61℃ ON), surge absorber, cooling water freeze protection, cooler freeze/superheat protection |
Output/Main unit abnormal output | Normal close/no-voltage (250 VAC/2 A/resistive load) |
Output / Temperature upper / Lower limit alarm | Normal close/no-voltage (250 VAC/2 A/resistive load) |